- Piece/Pieces
- 10
- , Piece/Pieces
- 1.00-
The RTV025A Series Hall Effect Voltage Sensor is a piece of electro-sensitive protective equipment with integrated adapter, which enables this device to be safely coupled with other electronic equipments. The diagnostics are enabled with the direct access via on-site voltage sensing. The protective field contours and all other parameters can be easily generated. The RTV025A Series Hall Effect Voltage Sensors are available in various size and specifications and can be from us at lower price.
Specifications :
Type Parameter | RTV5/25A | RTV10/25A | Unit |
Rated Input (Ipn) | 5 | 10 | mA |
Measure range (Ip) | 7 | 14 | mA |
Turns ratio (Np/Ns) | 5000 : 1000 | 2500 : 1000 | T |
Primary Coil resister | 650 | 200 | |
Secondary coil resister | 110 | 110 | |
Measure resister | +15 @ (+5)+10mAmax 100(min) 350 (Max) | ||
Rated output (Isn) | @Ip = +Ipn +25 + 0.5% | mA | |
Supply voltage | +15+5% | V | |
Power consumption | 20+IpX (Np/Ns) | mA | |
Zero offset current | @Ip = 0 +0.2 | mA | |
Offset current drift | @ - 40oC ~+85oC +0.5 | mA | |
Response time | 40 | S | |
Linearity | @Ip=0-+Ipn <0.2 | %FS | |
Galvanic isolation | @50HZ, AC, 1 min 2.5 | KV |
Applications :
- AC variable speed drives and servo motor drives
- Ariable speed drives
- Battery supplied applications
- Switch Mode Power Supplies (SMPS)
- Static converters for DC motor drives
- Power supplies for welding applications
- Uninterruptible Power supplies (UPS)
General Date :
| Value | Unit | Symbol |
Operating temperature | -40 to +85 | oC | TA |
Storage temperature | -40 to +125 | oC | TS |
Mass (Approx) | 20 | g | M |

- 20000 Per Month